How to Choose a Vartech Process Calibrator

Full process calibrator vs dedicated loop calibrator vs precision V/mA calibration, and why calibrator accuracy needs margin over the device under test - a buying guide to Vartech's calibrator range.

CIE Instruments CIE Instruments
· · 4 min read

Vartech's process calibrator range covers three instruments - a full temperature and process calibrator, a dedicated loop calibrator, and a precision V/mA signal calibrator - each aimed at a different part of instrumentation maintenance work. Choosing the right one comes down to what signal types you actually need to source and measure.

Full Process Calibrator or Dedicated Loop Calibrator?

The V 7220 R is the broadest instrument in the range - a 5-digit source-and-measure calibrator covering DC voltage, resistance, and thermocouple (multiple T/C types) and RTD (2-wire/3-wire/4-wire) simulation. This is the right instrument when your maintenance work spans multiple sensor types - temperature transmitters, RTDs, thermocouples and general process signals - from a single calibrator. The V 7221 B is more specialised: a dedicated 5-digit loop calibrator that sources 0-30 mA DC and measures ±35 mA / ±35 V DC, with sawtooth and triangle wave output for testing a loop's dynamic response - the right choice when your work is specifically 4-20 mA current loop calibration and verification rather than broader temperature sensor work.

Precision V/mA Calibration - The MS 7221

The MS 7221 is a 4½-digit V/mA process signal calibrator purpose-built for 4-20 mA loop work - sourcing and measuring 0-24 mA DC loop current and 0-10 V DC, with 0.015% mA accuracy and a built-in 24 V loop supply. That accuracy figure matters directly: when you're calibrating a transmitter or verifying a control loop's accuracy against a specification, the calibrator's own accuracy needs enough margin over the device under test that the measurement itself isn't the limiting factor. The built-in 24 V loop supply is a practical convenience - it means the calibrator can power a 2-wire transmitter loop directly during a bench check, without a separate loop power supply.

Calibrator accuracy vs. device-under-test accuracy

A calibrator should generally be at least 4 times more accurate than the device it's calibrating (a 4:1 test uncertainty ratio is the common industry guideline). Check the accuracy specification of the transmitter or instrument you're calibrating against, not just the calibrator's own headline number, before assuming a given calibrator is suitable for a specific calibration task.

Portability for Field Calibration

All three Vartech calibrators are handheld, battery-powered instruments with torch and backlight - built for field calibration work (checking a transmitter in situ on a process line) rather than requiring a bench setup. This matters for instrumentation technicians who need to walk a plant's transmitter population and calibrate or verify each one in place, rather than removing instruments to a lab bench.

Quick Reference by Use Case

  • Multi-sensor-type calibration work (T/C, RTD, DCV, resistance): V 7220 R.
  • Dedicated 4-20 mA loop calibration with dynamic waveform testing: V 7221 B.
  • Precision V/mA calibration with built-in loop supply: MS 7221.