Free downloads

Test report forms for the field

12 printable PDF forms for the people who test on site. Print one, fill it in by hand, and use the worksheet page for the formulas, tables and limits.

  • Free
  • No sign-up
  • Prints on A4
  • Formulas and limits included
Preview of the Insulation Resistance Test Report form

IEEE 43-2013 timed test

Insulation Resistance Test Report

Print it, fill it in on site and hand it over. Page 1 is the report form. Page 2 gives you the formulas, the temperature factor table and the limits, so you can work out every result by hand.

Preview of the Earth Resistance and Soil Resistivity Report form

IEEE 81 fall-of-potential and Wenner methods

Earth Resistance and Soil Resistivity Report

Page 1 is the electrode test with a printed graph for plotting the plateau. Page 2 is the Wenner soil resistivity worksheet with a depth correction table and a single-rod estimate.

Preview of the Overcurrent Relay Secondary Injection Report form

IEC 60255-151 inverse-time characteristics

Overcurrent Relay Secondary Injection Report

A commissioning form for phase overcurrent relays, with a plot sheet and a reference page that gives the expected operating time for any TMS.

Preview of the Transformer Oil BDV Test Report form

Dielectric strength of insulating oil, IEC 60156 style

Transformer Oil BDV Test Report

Record up to four oil samples on one sheet: six breakdown voltages each, with mean, lowest, highest, spread and a pass or fail against the limit for your voltage class. Page 2 has the procedure and the calculations.

Preview of the Transformer Insulation Resistance (Megger) Report form

HV to LV, winding to earth, core to earth

Transformer Insulation Resistance (Megger) Report

The standard set of transformer megger tests on one page, with a worksheet that corrects each reading to 20 °C and calculates DAR and PI.

Preview of the Cable Insulation Resistance Test Report form

Core to earth and core to core, DC test

Cable Insulation Resistance Test Report

A one-page megger record for power and control cables, with a per-kilometre column so cables of different lengths can be compared, and a reference page for test voltage and minimum values.

Preview of the Micro-Ohm Contact Resistance Test Report form

Four-wire Kelvin low-resistance measurement

Micro-Ohm Contact Resistance Test Report

Ten test lines for joints, lugs and contacts, with correction to 20 °C, percentage change against a baseline and a phase comparison box.

Preview of the Earth Pit Test and Maintenance Register form

Annual earth pit testing record

Earth Pit Test and Maintenance Register

A register for sites with many earth pits: one line each for location, type, measured resistance, limit, result, maintenance and next test date, with a checklist for each visit.

Preview of the AC Hi-Pot Withstand Test Report form

Power-frequency dielectric withstand test

AC Hi-Pot Withstand Test Report

A report form for AC high-voltage withstand tests, with a capacitive current check so you know before you start whether your test set can supply the load.

Preview of the Wiring Insulation Resistance Test Report form

Low-voltage final circuits, IEC 60364-6 values as commonly quoted

Wiring Insulation Resistance Test Report

A circuit-by-circuit certificate for a new installation, an extension or a periodic check, with a reference page for test voltage, minimum values, method and a quick cause finder.

Preview of the Motor Winding Test Report form

IEEE 43-2013 insulation, winding resistance and balance

Motor Winding Test Report

One sheet per motor: nameplate, insulation resistance with PI, winding resistance with correction to 75 °C and imbalance, and an optional no-load run. Page 2 has the formulas, a correction table and guide values.

Preview of the LV Panel Preventive Maintenance Checklist form

Preventive maintenance checklist with test record

LV Panel Preventive Maintenance Checklist

Page 1 is a tick-box checklist for the panel. Page 2 records the electrical tests that go with it: busbar insulation resistance, joint and contact resistance, and earthing.

Using the forms

  • Print on A4 at 100 % (no scaling). Page 1 of each form is the report you fill in. The following pages are worksheets and reference tables to keep with it.
  • Limits and constants come from the standards named on each form, as commonly quoted. Check them against the edition you work to, and use the stricter of those and your plant or customer specification.
  • Where a value is a common guide rather than a limit from a standard, the form says so.
  • These are calculation aids for qualified people. They do not replace the standard, the instrument manual or your site safety procedure.

Need the instrument as well?

CIE supplies insulation testers, earth testers, oil BDV testers, micro-ohm meters and relay test sets, with test certificate available on request.