— Vartech® Clamp Meters
V 266+ Digital Clamp Multimeter 1000A AC 600V
4000-count clamp multimeter with NCV, torch and three current ranges — the safer, smarter everyday clamp meter.
- Genuine Vartech product
- Expert technical support
- Pan-India delivery
- Competitive pricing
About This Instrument
The Vartech V 266+ is the step-up from the V 266, offering 4000-count resolution, three AC current ranges from 40 A to 1000 A, NCV detection and a built-in torch in a slimmer, lighter 220 g body. The lower 40 A current range gives far better resolution for small motors, branch circuits and lighting loads where the 1000 A range is too coarse — while NCV detection lets you safely confirm live conductors before probing. For working electricians who want a more capable daily clamp meter, the V 266+ delivers without complicating the workflow.
Key Features
- 4000-count resolution — twice the measurement resolution of standard 2000-count clamp meters for more precise current and voltage readings
- Three AC current ranges: 40 A / 400 A / 1000 A — the 40 A range resolves small motor currents and lighting loads with high accuracy; switch up to 1000 A for mains feeders
- Non-Contact Voltage (NCV) detection — identify energised conductors before probing; a critical safety feature absent from the basic V 266
- Built-in torch — illuminate dark distribution boards, panels and cable trays while both hands stay on the meter
- Resistance measurement up to 40 MΩ across 6 ranges — broader insulation spot-check and component testing capability than the V 266
- Lightweight at 220 g — noticeably easier to handle in overhead work and tight spaces; ideal for all-day field use
- NCV, diode test, continuity and data hold — the complete set of daily-use field functions
Technical Specifications
| Display | 3¾ Digits, 4000 Counts |
| Ranging | Manual |
| DC Voltage | 4 V / 40 V / 600 V | Accuracy: ±(0.8% rdg + 2 digits) |
| AC Voltage | 4 V / 40 V / 600 V | Accuracy: ±(1% rdg + 10 digits) |
| AC Current | 40 A / 400 A / 1000 A | Accuracy: ±(2.5% rdg + 10 digits) |
| Resistance | 400 Ω / 4 KΩ / 40 KΩ / 400 KΩ / 4 MΩ / 40 MΩ | Accuracy: ±(1.2% rdg + 2 digits) |
| Other Functions | NCV Test, Diode Test, Continuity Test, Torch, Data Hold, Low Battery Indication |
| Power | 2 × 1.5 V AAA batteries (optional) |
| Accessories | Test leads, carrying pouch, user manual, battery |
| Dimensions & Weight | 222 × 90 × 35 mm | ~220 g (including battery) |
Specifications are sourced from the official Vartech product catalogue. Download the catalogue above for the full datasheet.
Interested in the Vartech V 266+? Get a quote today.
Email us with your model, quantity and application — we respond within one business day.