— Industries · Applications

Power Utilities

Power utilities require insulation testing on HV cables, transformers, and switchgear at commissioning and during periodic maintenance. Earth resistance testing is mandatory at every substation. Transformer oil quality (BDV) testing is performed before energisation and at routine maintenance intervals. Protection relay testing is essential for grid security.

PGCIL, WBSETCL, NTPC, State Electricity Boards

Instruments Used in Power Utilities

CIE/444 — Insulation Tester — Metal Body, Hand-Driven Featured

CIE/444

Insulation Tester — Metal Body, Hand-Driven

Hand-cranked analog insulation tester in anti-magnetic aluminium body — no batteries required. 100 V to 5000 V.

CIE/666 — Insulation Tester — Wooden Body, Hand-Driven Featured

CIE/666

Insulation Tester — Wooden Body, Hand-Driven

Hand-cranked analog insulation tester in seasoned wooden body — up to 10,000 V. Wider range than metal-body CIE/444.

CIE/222M — Analog Earth Tester — Metal Body Featured

CIE/222M

Analog Earth Tester — Metal Body

Hand-driven analog earth tester — 3-terminal (earth resistance) and 4-terminal (earth resistance + soil resistivity). ±5% accuracy per IS: 9223/1979.

RTS-33 — Three-Phase Relay Test Set

RTS-33

Three-Phase Relay Test Set

Three-phase, two-unit relay test set — 0–360° phase angle, 0–50 A current, 415 V 3-phase input. For distance, directional, and differential relay testing.

DIT-2500 — Digital Insulation Tester + Multimeter — up to 2500 V Featured

DIT-2500

Digital Insulation Tester + Multimeter — up to 2500 V

Combined digital insulation tester (100 V–2500 V, 50 GΩ) and True-RMS multimeter with DAR, PI, capacitance, and diode test. CAT III 1000 V / CAT IV 600 V.

DIT-5000 — Digital Insulation Tester — up to 5000 V / 200 GΩ

DIT-5000

Digital Insulation Tester — up to 5000 V / 200 GΩ

Auto-ranging digital insulation tester to 5000 V with HV LED indicator, auto zero calibration, and large-character LCD. 6 × AA batteries.

Why These Instruments

CIE/444

Electrical maintenance of rotating plant equipment and stationary apparatus

CIE/666

Electrical maintenance of rotating plant equipment and stationary apparatus

CIE/777

Sustained insulation and polarization index (PI) testing on large rotating plant

CIE/222M

Earth resistance measurement for power circuits and lightning protection systems

CIE/7050

Transformer oil dielectric strength testing before energisation

RTS-33

Distance relay commissioning

Tell us your power utilities requirement — we'll recommend the right instrument.

Our team has been serving this sector for over 60 years. We know which instrument fits your application.